How is the conditional requirement for the BASIX pathway calculated?
How is the conditional requirement for the BASIX pathway calculated?
The Conditional Requirement (15C.0) for the BASIX Pathway is calculated as a 10% reduction relative to the maximum allowable aggregate heating and cooling energy for the project climate regions as per the BASIX thermal comfort compliance criteria. A graphical explanation has been attached to this FAQ.
For example, if the BASIX energy target for a project in a climate region is 15,
- then the maximum allowable aggregate heating a cooling energy is 85 (or 100 - 15)
- a 10% reduction relative to the above would be 76.5 [or 85-(10% x 85)]
- the Conditional Requirement would be a 23.5% reduction (or 100 - 76.5)
Attachments
The following files are linked to this FAQ:
Rating Tools
This FAQ is related to the following Rating Tools, Categories or Credits:
- Green Star - Design & As Built v1.1 / Energy / 15 Conditional Requirement - Greenhouse Gas Emissions
- Green Star - Design & As Built v1.2 / Energy / 15 Greenhouse Gas Emissions - Conditional Requirement
Disclaimer
When used on Green Star projects, make sure to:
These FAQs are:
- provided as additional technical assistance for Green Star users.
- optional and free to use on Green Star projects.
When used on Green Star projects, make sure to:
- state the FAQ number on the Submission Template.
- click on "Download" to save the FAQ.
- include the PDF in the submission.
The GBCA reserves the right to add or remove FAQ at our discretion.