GBCA notes that the intent of the criterion 'Localised Lighting Control' in Green Star - Design & As-Built is to provide occupants with the ability to control the lighting in their immediate environment. 

In an open plan/ activity-based working environment, for example, an office setting or educational facilities i.e. libraries, project teams may demonstrate compliance by providing different lighting zones across 95% of the nominated area. It is noted that the lighting zones should be designed to suit different tasks, for example:

  • Some areas may have soft lighting, such as areas with daylight during the nominated hours.
  • Some areas may have a high degree of lighting control, including turning the lights on and off and adjusting their light levels and; 
  • Other areas where light is shone directly on the workstation.

Where compliance is being demonstrated through varied lighting zones, project teams must demonstrate how all the regular occupants in the project have access to all the spaces provided. The localized lighting strategy should be complemented with a communication strategy, outlining how individual lighting control may be achieved by occupants by occupying different lighting zones. The project team may choose to use the tenant fit out guide to communicating this message.

Where projects are delivered with cold shell spaces or where the scope of the rating is base building, project teams can demonstrate compliance by installing a DALI system within the base building which can be utilised by the tenant to deliver localised lighting control as per FAQ - 199. 

 





Rating Tools

This FAQ is related to the following Rating Tools, Categories or Credits:

  • Green Star - Design & As Built v1 / Indoor Environment Quality / 11.3 Lighting Comfort - Localised Lighting Control
  • Green Star - Design & As Built v1.1 / Indoor Environment Quality / 11.3 Lighting Comfort - Localised Lighting Control
  • Green Star - Design & As Built v1.2 / Indoor Environment Quality / 11.3 Lighting Comfort - Localised Lighting Control
  • Green Star - Design & As Built v1.3 / Indoor Environment Quality / 11.3 Localised Lighting Control
  • Green Star - Interiors v1 / Indoor Environment Quality / 10.3 Lighting Comfort - Localised Lighting Control
  • Green Star - Interiors v1.1 / Indoor Environment Quality / 10.3 Lighting Comfort - Localised Lighting Control
  • Green Star - Interiors v1.2 / Indoor Environment Quality / 10.3 Lighting Comfort - Localised Lighting Control
  • Green Star - Interiors v1.3 / Indoor Environment Quality / 10.3 Localised Lighting Control


Disclaimer

These FAQs are:

  • provided as additional technical assistance for Green Star users.
  • optional and free to use on Green Star projects.

When used on Green Star projects, make sure to:
  • state the FAQ number on the Submission Template.
  • click on "Download" to save the FAQ.
  • include the PDF in the submission.

The GBCA reserves the right to add or remove FAQ at our discretion.





Have more questions?

Submit a question by selecting an option below: