Status Certified
-
Address
Level 1, 170 Railway Parade West Leederville WA
- Certified Tue 20 Sep 2016
- Score 64
- Applicant(s)
Western Australian Local Government Association
-
Architect
HASSELL Ltd
-
ESD Consultant
AECOM Australia Pty Ltd
|
Category Achievements
Management
- Comprehensive pre-commissioning, commissioning and quality monitoring occurred for the tenancy.
- Provided a comprehensive, yet simple Tenant Guide for the relevant building and tenancy systems to the users and owner.
- The contractor implemented a Waste Management Plan and 80% of construction waste by weight was re-used or recycled during fitout works.
Indoor Environment Quality
- 100% improvement above the the fresh air rate requirements in AS 1668.2-1991 promotes healthy indoor environment.
- Volatile organic compounds are minimised in 95% of painted surfaces and all carpets.
- A dedicated tenant exhaust riser is installed to remove indoor pollutants from printing and photocopy areas.
- A carbon dioxide monitoring system is installed to track and adjust ventilation rates with low carbon dioxide levels.
- 30% of work settings have good daylight levels for building users.
- Automated blinds and screens with a Visual Light Transmittance of less than 10% are installed in the tenancy to reduce daylight glare, with manual overrides.
- Installed high frequency ballasts reduce occupants' eye strain from low frequency flicker.
- 60% of workstations have direct line of site to outdoor environments.
Energy
- The tenancy achieves at least a 5 Star NABERS (formerly ABGR) rating, with an additional 20% CO2 reduction.
- Sub-metering is installed for substantive energy uses within the tenancy.
- Individual switches are installed for enclosed spaces and zones in accessible locations. Further, 95% of the Net Lettable Area (NLA) contains an individually addressable lighting system.
Transport
- Many public transport networks operate in close proximity with frequent peak hour services.
- Car parking provisions do not exceed the minimum local planning allowance.
- Cyclist facilities are available, with secure bicycle storage for 10% of tenancy occupants and accessible shower and change facilities.
Water
- The use of potable water is designed to be a leader in efficiency.
- All dishwashers in the tenancy are 5A rated.
Materials
- The tenancy provided workstations with reduced environmental impact, relative to available alternatives.
- Alternative materials replace 60% (by cost) of total PVC costs.
- Flooring throughout the tenancy has a reduced environmental impact, relative to available alternatives.
- The tenancy provided chairs with reduced environmental impact, relative to available alternatives.
- The tenancy provided tables with reduced environmental impact, relative to available alternatives.
- The tenancy provided storage units with reduced environmental impact, relative to available alternatives.
- Ceilings in the tenancy have a reduced environmental impact, relative to available alternatives.
Land Use & Ecology
- The tenancy is located in a Green Star Office As Built 5 Star rated building.
- The building management is contractually required to implement environmental initiatives concerning maintenance and monitoring of various tenancy aspects.
- The tenancy lease agreement requires participation in a number of monitoring and maintenance intiatives for the tenancy.
- 90% of Net Lettable Area (NLA) of the tenancy is a fully integrated fitout with the base building.
Emissions
- No refrigerants are used in this project.
- All thermal insulation avoids the use of ozone-depleting substances in both manufacture and composition.